Applies to: Wet grinding module

Technical data

Dimensions (W/D/H)

 

Unit

Value

Footprint (approx.)

- with feet

mm

in

382 x 455 x 510

15.0 x 17.9 x 20.1

Footprint (approx.)

- with castors

mm

in

382 x 455 x 570

15.0 x 17.9 x 22.4

Weight

 

Unit

Value

Machine insert (approx.)

kg

lbs

16

35.3

Housing (approx.)

kg

lbs

12

26.5

Accessories (approx.)

kg

lbs

3

6.6

Total (approx.)

kg

lbs

31

68.3

External air extraction system

 

Unit

Value

Minimum extraction capacity

l/min

cfm

2,500 (at 220 hPa)

88.3 (at 3.2 psi)

Suction unit

 

Designed for the commercial use in the dental sector

Equipped with a filter of the filter class M

Ambient conditions

 

Unit

Value

Relative humidity

 

80 %, non-condensing

Ambient temperature for storage / transport

°C

°F

‑20 – 60

-4 – 140

Ambient temperature for operation

°C

°F

10 – 30

50 – 86

Location type

 

Indoor

Maximum height above mean sea level

m

ft

2000

6561

Ambient air (IEC 60664-1)

 

Dust free, pollution degree 2

Electromagnetic radiation (IEC 61326-1)

 

Residential, business and commercial areas

Electromagnetic interference (IEC 61326-1)

 

Industrial environment

Cooling liquid system

 

Unit

Value

Cooling liquid

 

Emulsion of water and the cooling lubricant Tec Liquid Pro

Maximum amount of cooling liquid

l

qt

15

15.85

     

Coarse filter mat

 

For rough particles

Flat pleated filter

 

To protect the air extraction system

Fine filter cartridge

 

Pore size 5 µm

Sound emission

Operating condition

Unit

Value

Sound pressure level

dB(A)

81

Sound power level

dB(A)

95

Measuring condition

Value

Machined material

VITABLOCS Mark II

Operating condition

Grind (full load), with Aspiration and Wet grinding module

Measured value

Sound pressure level (distance: 1 m)

Measurement uncertainty

4 dB(A)

Measurement according to

ISO 3746, accuracy class 3

Connections

 

Unit

Value

Power connector

(and maximum power consumption in watts)

V AC

Hz

W

100 – 240

50/60

24

Glass fuse T6,3A L250V

Switch input for cooling liquid pump

 

Yes

Hose connection for the external air extraction unit

Ø

45 mm

Hose connection for connecting hose

Ø

45 mm

Hose connection for cooling liquid

Ø