Applies to: DentalCAM & DentalCNC 8.09

Error code -1101 or -3101 – Error while loading the blank

This error code can occur while the machine is loading a blank from the blank magazineClosed Part of the blank changer in which you store the blanks for automatic loading. into the working chamber.

It indicates that the blank gripper could not reach its end position to remove the blank from the blank magazineClosed Part of the blank changer in which you store the blanks for automatic loading..

The corresponding end switch or sensor did not send a signal.

There is an extended version of this troubleshooting guide available for vhf certified service employees:

Interactive troubleshooting guide

Is the blank properly mounted into the blank magazine?

How to check this:

  1. Open the multi-purpose compartment.
  2. Check whether the blank in the loading position is properly mounted. Mounting blanks and block holders in the blank magazine

The loading position (marked orange)